- This is used to match one pure resistance to another using L, Pi or T reactive
- networks. Since the networks use only reactive components they are lossless.
- You could for example match 75 Ohms to 50 Ohms. The match is perfect at only
- one frequency. If you need wide-band matching, use a resistive (lossy) network.
- Equations were taken from: Introduction to RF Design, by W.H. Hayward.
- Always make Rin < Rout.
-
-